3\4Core Cable

0.6/1 kV XLPE Insulated, Multi-Core Cables With Copper Conductor3

 
 
 
   
 
 
Code
YXV-R, CU/XLPE/PVC, N2XY
R, Stranded conductor
 
Standards
TS IEC 60502, VDE 0276
 
Technical Data
Max. operating temperature  : 90°C
Max. short circuit temperature  : 250°C (max. 5 sec.)
Rated voltage  : 0.6/1 kV
Min. bending radius  : 12 x D
: Cable outer diameter
 
Application
These cables have a low dielectric loss, used in indoors and
outdoors, in cable ducts, underground, in power or switching
stations, local energy distributions, industrial plants, where there
is no risk of mechanical damage.
 
Construction
1. Stranded copper conductor.
2. XLPE insulation.
3. Filler.
4. PVC outer sheath.
 

DIMENSION AND WEIGHTS ELECTRİCAL PROPERTIES
Nominal Cross-Section Overall Diameter (approx) Net Weight (approx) Delivery Lenght DC Conductor Resistance at 20C Current Carrying Capacity
mm2 mm kg/km m ohm/km In ground at 20 ·C (A) In aird at 30 ·C (A)
3×1,5 11.5 180 1000 12.1 30 24
3×2,5 12.5 230 1000 7.41 40 32
3×4 13.5 300 1000 4.61 52 42
3×6 14.5 370 1000 3.08 64 53
3×10 17.0 550 1000 1.83 86 73
3×16 19.0 700 1000 1.15 111 96
3×25 22.5 1150 1000 0.727 143 130
3×35 24.5 1500 1000 0.524 173 160
3×50 27.5 1950 1000 0.387 205 195
3×70 32.0 2750 1000 0.268 252 247
3×95 36.0 3600 1000 0.193 303 305
3×120 40.0 4500 1000 0.153 346 355
3×150 44.5 5600 500 0.124 390 407
3×185 49.0 6950 500 0.0991 441 469
3×240 56.0 9000 500 0.0754 511 551
3×300 63.0 11200 250 0.0601 580 638
3×400 72.0 14750 250 0.0470 663 746

 

0.6/1 kV XLPE Insulated, Multi-Core Cables With Copper Conductor4

 
 
 
   
 
 
code
YXV-U, YXV-R, CU/XLPE/PVC, N2XY
U, Soild Conductor
R, Stranded Conductor
 
Standards
S IEC 60502, VDE 0276
 
Technical Data
Max. operating temperature  : 90°C
Max. short circuit temperature  : 250°C (max. 5 sec.)
Rated voltage  : 0.6/1 kV
Min. bending radius  : 12 x D
: Cable outer diameter
 
Application
These cables have a low dielectric loss, used in indoors and outdoors, in cable ducts, underground, in power or switching
stations, local energy distributions, industrial plants, where there is no risk of mechanical damage.
 
Construction
1. Solid or stranded copper conductor.
2. XLPE insulation.
3. Filler.
4. PVC outer sheath.
 
DIMENSION AND WEIGHTS ELECTRİCAL PROPERTIES
Nominal Cross-Section Overall Diameter (approx) Net Weight (approx) Delivery Lenght DC Conductor Resistance at 20C Current Carrying Capacity
mm2 mm kg/km m ohm/km In ground at 20 ·C (A) In aird at 30 ·C (A)
4×1,5 12.0 200 1000 12.1 30 24
4×2,5 13.0 250 1000 7.41 40 32
4×4 14.5 350 1000 4.61 52 42
4×6 15.5 450 1000 3.08 64 53
4×10 18.5 700 1000 1.83 86 73
4×16 20.5 950 1000 1.15 111 96
4×25 24.5 1400 1000 0.727 143 130
4×35 27.0 1850 1000 0.524 173 160
4×50 30.5 2500 1000 0.387 205 195
4×70 35.5 3500 1000 0.268 252 247
4×95 39.5 4650 1000 0.193 303 305
4×120 44.5 5900 500 0.153 346 355
4×150 49.0 7200 500 0.124 390 407
4×185 54.5 8950 500 0.0991 441 469
4×240 62.0 11600 250 0.0754 511 551
4×300 70.0 14400 250 0.0601 580 638
4×400 80.0 19000 250 0.0470 663 746